Internet DRAFT - draft-zhang-nvo3-yang-active-active-cfg

draft-zhang-nvo3-yang-active-active-cfg



 



INTERNET-DRAFT                                              Mingui Zhang
Intended Status: Standards Track                              Jinwei Xia
                                                                  Huawei
                                                                 Fu Qiao
                                                            China Mobile
                                                        Muhammad Durrani
                                                                 Brocade
                                                                Zu Qiang
                                                                Ericsson
                                                             Sujay Gupta
                                                             IP Infusion
Expires: June 18, 2016                                 December 16, 2015

          YANG Data Model for Active-Active NVEs Configuration
             draft-zhang-nvo3-yang-active-active-cfg-03.txt

Abstract

   When a Tenant System is not collocated with Network Virtualization
   Edges (NVEs), it's possible for this Tenant System to connect to a
   group of NVEs or a single NVE with multiple underlay IP addresses to
   use the active-active multihoming L2/L3 service provided by these
   NVEs.

   This document defines the YANG data model that can be used to
   configure NVEs of a NVO3 network to achieve active-active multi-
   homing.

Status of this Memo

   This Internet-Draft is submitted to IETF in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF), its areas, and its working groups.  Note that
   other groups may also distribute working documents as
   Internet-Drafts.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   The list of current Internet-Drafts can be accessed at
   http://www.ietf.org/1id-abstracts.html

   The list of Internet-Draft Shadow Directories can be accessed at
   http://www.ietf.org/shadow.html
 


Mingui Zhang, et al      Expires June 18, 2016                  [Page 1]

INTERNET-DRAFT   YANG Data Model for Active-Active NVEsDecember 16, 2015


Copyright and License Notice

   Copyright (c) 2015 IETF Trust and the persons identified as the
   document authors. All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document. Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document. Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.


Table of Contents

   1. Introduction  . . . . . . . . . . . . . . . . . . . . . . . . .  3
   2. Acronyms and Terminology  . . . . . . . . . . . . . . . . . . .  3
     2.1. Acronyms  . . . . . . . . . . . . . . . . . . . . . . . . .  3
     2.2. Terminology . . . . . . . . . . . . . . . . . . . . . . . .  3
   3. The YANG Model for NVO3 Configuration . . . . . . . . . . . . .  3
     3.1. The Configuration Values  . . . . . . . . . . . . . . . . .  3
       3.1.1. The End Device ID . . . . . . . . . . . . . . . . . . .  3
       3.1.2. The NVE IP List . . . . . . . . . . . . . . . . . . . .  4
         3.1.2.1. The Priority  . . . . . . . . . . . . . . . . . . .  4
         3.1.2.2. The Virtual Access Points List  . . . . . . . . . .  4
       3.1.4. The Virtual Network Instance  . . . . . . . . . . . . .  4
       3.1.3. The Attached Tenant System Address List . . . . . . . .  4
     3.2. Model Structure . . . . . . . . . . . . . . . . . . . . . .  5
     3.3. YANG Module Code  . . . . . . . . . . . . . . . . . . . . .  5
   4. Security Considerations . . . . . . . . . . . . . . . . . . . .  8
   5. IANA Considerations . . . . . . . . . . . . . . . . . . . . . .  8
   6. References  . . . . . . . . . . . . . . . . . . . . . . . . . .  8
     6.1. Normative References  . . . . . . . . . . . . . . . . . . .  8
     6.2. Informative References  . . . . . . . . . . . . . . . . . .  9
   Author's Addresses . . . . . . . . . . . . . . . . . . . . . . . . 10










 


Mingui Zhang, et al      Expires June 18, 2016                  [Page 2]

INTERNET-DRAFT   YANG Data Model for Active-Active NVEsDecember 16, 2015


1. Introduction

   Network virtualization over Layer 3 tunnels (NOV3) is a promising way
   for large scale data center network provision. In NVO3 architecture,
   the Network Virtualization Edge (NVE) sits at the edge of an overlay
   network of NVO3 and provides virtualized L2 and/or L3 service to the
   Tenant Systems (TS). At the Split-NVE scenario, where the NVE and the
   TS are not located in the same server (for example, the NVE resides
   on an adjacent switch to which the server is attached), it is
   possible that a Tenant System is multihomed to various NVEs or a
   single NVE with multiple under IP addresses. In that case, it's
   desirable that these NVEs provide the Tenant System with active-
   active multihoming.

   This document provides the YANG model for configuring NVEs to offer
   Tenant Systems with active-active L2 and/or L3 access, which admits
   centralized provisioning of virtualization (i.e. NVA based).

2. Acronyms and Terminology

2.1. Acronyms

   NVO3: Network Virtualization Overlays
   NVE: Network Virtualization Edge
   NVA: Network Authority Virtualization
   VNI: Virtual Network Instance
   VAP: Virtual Access Points [RFC7365]
   AANVE: Active-Active NVEs. The AANVE denotes the group of NVEs that
     offer active-active multi-homing VAPs to Tenant Systems. 

2.2. Terminology

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in RFC 2119 [RFC2119].

   Familiarity with [RFC7364], [RFC7365], [I-D.ietf-nvo3-dataplane-
   requirements] and [RFC7348] is assumed in this document.

3. The YANG Model for NVO3 Configuration

3.1. The Configuration Values

3.1.1. The End Device ID

   The 'end-id' is the identification of an end device [RFC7365] which
   can either be an L2 (a LAN) or L3 (a subnetwork) network device. This
   ID also identifies the redundant group of NVEs that offers the L2/L3
 


Mingui Zhang, et al      Expires June 18, 2016                  [Page 3]

INTERNET-DRAFT   YANG Data Model for Active-Active NVEsDecember 16, 2015


   active-active access to the NVO3 overlay network. This ID may be
   shared among different Virtual Networks (a.k.a, Closed User Groups,
   CUGs [RFC7365]).

3.1.2. The NVE IP List

   The 'nve-ip', which is the underlay IP address, can either be IPV4 or
   IPv6 [RFC7365].

   If the network is configured according to the YANG model defined in
   this document, NVEs in an AANVE will discover each other's 'nve-ip'
   while remote NVEs learn the grouping of NVE IPs that are offering
   multi-homing to an end device.

3.1.2.1. The Priority

   For a BUM packet, the AANVE MUST determine a unique egress NVE
   otherwise the multi-homed Tenant System will see frame duplication.
   The 'priority' describes the primary and backup NVEs in an AANVE per
   VNI. For the BUM packet, the primary in the AANVE is supposed to act
   as the unique outgoing NVE. Other backup NVEs MUST NOT egress the BUM
   packet onto the end device.

3.1.2.2. The Virtual Access Points List

   The 'vap-list' specifies the interfaces that a NVE uses to connect to
   the multi-homed end device. For those VAPs listed in the 'vap-list',
   packets with ingress NVEs which are listed in the same AANVE as the
   VAPs' hosted NVE MUST NOT be egressed. This embodies the split-
   horizon.

   When a NVE is configured to have more than one VAPs for a given
   AANVE, the NVE MUST determine a unique VAP to deliver a received
   packet to the local tenant system.

3.1.4. The Virtual Network Instance

   The 'vni' specifies the identification of Virtual Network Instance
   [RFC7365]. The 'multi-attached-info' configuration is valid per VNI.

3.1.3. The Attached Tenant System Address List

   The 'attached-ts-addresses' given in the model is used to configure
   NVEs within a VNI the Tenant System MAC/IP addresses attached to the
   multi-homed end device. From the configuration, remote NVEs learn
   these addresses are multi-homed to the nve-ip listed in the 'nve-ip-
   list', therefore packet destined to these addresses are reachable via
   any of the listed NVEs. One of the learned NVEs will be installed
 


Mingui Zhang, et al      Expires June 18, 2016                  [Page 4]

INTERNET-DRAFT   YANG Data Model for Active-Active NVEsDecember 16, 2015


   into the data plane as the egress NVE on a per-VNI or per-ts-address
   basis.

   For L2 service, the MAC list in the configuration is prone to be more
   unstable than other part. Control protocols can be used to push the
   update of the MAC list per VNI. For example, [I-D.dunbar-nvo3-nva-
   mapping-distribution] can be used to distribute the MAC address of
   Tenant Systems. When the updated MAC list is pushed, it's REQUIRED
   that the 'end-id' is taken along. Through hearing the 'end-id',
   remote NVEs can identify the AANVE to which the pushed MAC addresses
   are attached.

3.2. Model Structure

   module: ietf-nvo3-aanve
      +--rw active-active-nve-groups* [end-id]
         +--rw end-id                 END-DEVICE-ID
         +--rw multi-attached-info
            +--rw nve-ip-list* [nve-ip]
            |  +--rw nve-ip      NVE-IP
            |  +--rw priority?   enumeration
            |  +--rw vap-list*   if:interface-ref
            +--rw vni?                     VNI
            +--rw attached-ts-addresses*   TS-ADDRESS

  Figure 3.1. The tree of YANG module for active-active configuration

3.3. YANG Module Code

   <CODE BEGINS> file "ietf-nvo3-aanve@2015-12-16.yang"

   module ietf-nvo3-aanve {
     namespace "urn:ietf:params:xml:ns:yang:ietf-nvo3-aanve";
     prefix ietf-nvo3-aanve;
     import ietf-inet-types {
       prefix "inet";
     }
     import ietf-interfaces {
       prefix if;
     }
     import ietf-yang-types {
       prefix yang;
     }

     organization "IETF NVO3 Working Group";
     contact "zhangmingui@huawei.com";
     description
       "The module for nvo3 active-active edge configuration";
 


Mingui Zhang, et al      Expires June 18, 2016                  [Page 5]

INTERNET-DRAFT   YANG Data Model for Active-Active NVEsDecember 16, 2015


     revision 2015-12-16 {
       description
         "Initial revision.";
       reference "RFC 7364";
     }

     typedef NVE-IP {
       type union {
         type inet:ipv4-address;
         type inet:ipv6-address;
       }
       description
         "Defines addresses of different nves, IPv4 or IPv6";
     }

     typedef END-DEVICE-ID{
       type string;
       description
         "The identification of the end device that is 
         multi-attached to those NVEs given by the 'nve-ip-list'; If the
         end device is an MC-LAG, it's an 8-octet value ID 
         according to Section 5.3.2 in 802.1ax-2008";
     } 

     typedef VNI {
        type uint32{
         range "1 .. 16777215";
       }
       description
         "Virtual Network Instance (VNI)";
      }

     typedef TS-ADDRESS{
       type union{
         type yang:mac-address;
         type inet:ipv4-address;
         type inet:ipv6-address;
       }
       description
         "The address of the Tenant System";
     }

     list active-active-nve-groups{
       key "end-id";
       leaf end-id{
         type END-DEVICE-ID;
         description
           "The identification of the end device that is 
 


Mingui Zhang, et al      Expires June 18, 2016                  [Page 6]

INTERNET-DRAFT   YANG Data Model for Active-Active NVEsDecember 16, 2015


            multi-attached to the NVEs given in the 'nve-ip-list'.";
       }

       container multi-attached-info{
         list nve-ip-list{
           key "nve-ip";
           leaf nve-ip{
             type NVE-IP;
   	  description
   	    "The IP address of the NVE.";
           }
           description
             "Any NVE can deliver traffic of any VNI in the 'vni-list' 
             in this container";      

           leaf priority {
              type enumeration {
                enum primary {
                  value "1";
                  description
                    "Primary egress NVE.";
                }
                enum backup {
                  value "2";
                  description
                    "Backup egress NVE.";
                }
              }
              description
                "Simple priority for distinguishing between primary 
                and backup egress NVEs in an AANVE for BUM packets.
                Backup egress NVEs MUST NOT egress a BUM packet.";
           }

           leaf-list vap-list{
             type if:interface-ref;
             description
               "This nve uses these interfaces to attach the end device 
               link identified by the 'end-id'. These interfaces MUST 
               NOT egress any packet whose source NVE is listed in 
               the 'nve-ip-list'";//split horizon
           }
         }

         leaf vni {
           type VNI;
           description
             "A VNI enabled for the end device identified by the 
 


Mingui Zhang, et al      Expires June 18, 2016                  [Page 7]

INTERNET-DRAFT   YANG Data Model for Active-Active NVEsDecember 16, 2015


             'end-id'";
         }

         leaf-list attached-ts-addresses{
           type TS-ADDRESS;
           description
             "The list of the Tenant System Addresses that are 
             connected to the end device identified by the 'end-id'. For
             any address in this list, the remote nve can sent traffic 
             towards it within the 'vni' via any nve given in the 
             nve-ip-list'";
         }    
         description
           "The information about the multi-attached NVE group.";
       }
       description
         "The information for the group of NVEs that are multiply
         attached by a TS.";
     }     
   }
   <CODE ENDS>

4. Security Considerations

   This document raises no new security issues.

5. IANA Considerations

   The namespace URI defined in Section 3.3 need be registered in the
   IETF XML registry [RFC3688]. 

   This document need to register the 'ietf-nvo3-aanve' YANG module in
   the YANG Module Names registry [RFC6020].

6. References 

6.1. Normative References

   [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
             Requirement Levels", BCP 14, RFC 2119, March 1997.

   [RFC3688] Mealling, M., "The IETF XML Registry", BCP 81, RFC 3688,
             January 2004.

   [RFC6020] Bjorklund, M., Ed., "YANG - A Data Modeling Language for
             the Network Configuration Protocol (NETCONF)", RFC 6020,
             October 2010.

 


Mingui Zhang, et al      Expires June 18, 2016                  [Page 8]

INTERNET-DRAFT   YANG Data Model for Active-Active NVEsDecember 16, 2015


6.2. Informative References

   [I-D.ietf-nvo3-arch] D. Black, J. Hudson, et al, "An Architecture for
             Overlay Networks (NVO3)", draft-ietf-nvo3-arch, work in
             progress.

   [RFC7364] Narten, T., Ed., Gray, E., Ed., Black, D., Fang, L.,
             Kreeger, L., and M. Napierala, "Problem Statement: Overlays
             for Network Virtualization", RFC 7364, October 2014.

   [RFC7365] Lasserre, M., Balus, F., Morin, T., Bitar, N., and Y.
             Rekhter, "Framework for Data Center (DC) Network
             Virtualization", RFC 7365, October 2014.

   [RFC7348] Mahalingam, M., Dutt, D., Duda, K., Agarwal, P., Kreeger,
             L., Sridhar, T., Bursell, M., and C. Wright, "Virtual
             eXtensible Local Area Network (VXLAN): A Framework for
             Overlaying Virtualized Layer 2 Networks over Layer 3
             Networks", RFC 7348, August 2014.

   [I-D.ietf-nvo3-dataplane-requirements] Nabil Bitar, Marc Lasserre, et
             al, "NVO3 Data Plane Requirements", draft-ietf-nvo3-
             dataplane-requirements, working in progress.

   [I-D.dunbar-nvo3-nva-mapping-distribution] L. Dunbar, D. Eastlake,
             "NVA Address Mapping Distribution (NAMD) Protocol", draft-
             dunbar-nvo3-nva-mapping-distribution, work in progress.





















 


Mingui Zhang, et al      Expires June 18, 2016                  [Page 9]

INTERNET-DRAFT   YANG Data Model for Active-Active NVEsDecember 16, 2015


Author's Addresses


   Mingui Zhang
   Huawei Technologies
   No. 156 Beiqing Rd. Haidian District,
   Beijing 100095 
   P.R. China
   	
   EMail: zhangmingui@huawei.com


   Jinwei Xia
   Huawei Technologies
   No. 101 Software Rd. YuHua District,
   Nanjing 210012 
   P.R. China

   EMail: xiajinwei@huawei.com


   Fu Qiao
   China Mobile 

   EMail: fuqiao@chinamobile.com


   Muhammad Durrani
   Brocade
   130 Holger Way
   San Jose, CA 95134

   EMail: mdurrani@brocade.com


   Zu Qiang
   Ericsson
   8400, boul. Decarie
   Ville Mont-Royal, QC,
   Canada

   EMail: Zu.Qiang@Ericsson.com


   Sujay Gupta
   IP Infusion, 