HTTP/1.1 200 OK Date: Tue, 09 Apr 2002 11:48:01 GMT Server: Apache/1.3.20 (Unix) Last-Modified: Thu, 18 Sep 1997 11:15:00 GMT ETag: "3ddacb-16828-34210d34" Accept-Ranges: bytes Content-Length: 92200 Connection: close Content-Type: text/plain Fibre Channel Working Group Kha Sin Teow INTERNET-DRAFT Brocade Communications Systems, Inc. Version 1.9 February 7, 1997 Definitions of Managed Objects for the Fabric Element in Fibre Channel Standard Status of this Memo This document is an Internet Draft. Internet Drafts are working documents of the Internet Engineering Task Force (IETF), its Areas, and its Working Groups. Note that other groups may also distribute working documents as Internet Drafts. Internet Drafts are valid for a maximum of six months and may be updated, replaced, or obsoleted by other documents at any time. It is inappropriate to use Internet Drafts as reference material or to cite them other than as a "working draft" or "work in progress." Distribution of this memo is unlimited. Please send comments to the ANSI X3T11 Fibre Channel Working Group: fibre-channel-ext@Think.COM. Abstract This memo defines an experimental portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it defines the objects for managing the operations of the Fabric Element portion of the Fibre Channel Standard defined in [1], [2] and [3]. This memo specifies a MIB module in a manner that is both compliant to the SNMPv2 SMI, and semantically identical to the peer SNMPv1 definitions. There is a companion memo [10], that defines the objects for managing the operations of the Node portion of the Fibre Channel Standard (FC). Expiration Date July 1997 [Page 1] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 1. Overview A Fibre Channel Fabric is an entity which interconnects Node Ports (N_Ports). It provides transport and routing functions. In essence, a Fabric is a network of N_Ports that may communicate with one another. A Fabric is composed of one or more Fabric Element that are interconnected via Inter-element Links (IEL). A Fabric Element is the smallest unit of a Fabric that meets the definition of a Fabric. It must consist of at least three external ports to connect to either N_Ports or other Fabric Elements. In general, a Fabric Element port may be of one of the following types: (1) F_Port, a fabric port to connect to an N_Port; (2) E_Port, an expansion port to connect to another Fabric Element; (3) M_Port, a node port that resides within the Fabric; or (4) FL_Port, a fabric port that also supports a FC Arbitrated Loop [12]). This memo shall define objects related to a Fabric Element and its F_Ports. Objects related to other types of FC ports shall be defined in future. 1.1. Management View of a Fabric Element From the management perspective, it is helpful to view a Fabric Element to be consisting of multiple "modules". Each module is a grouping, either physical or logical, of one or more ports that may be managed as a sub-entity within the Fabric Element. This module mapping is recommended but optional. A vendor may elect to put all ports into a single module, or to divide the ports into modules that do not match physical divisions. The object fcFeModuleCapacity, which has a maximum value of 256, indi- cates the maximum number of modules that a given Fabric Element may con- tain. This value must remain constant from one management restart to the next. Each module is uniquely identified by a module number in the range of 1 through fcFeModuleCapacity inclusive. Modules may come and go without causing a management reset (of sysUpTime), and may be sparsely numbered Expiration Date July 1997 [Page 2] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 within the Fabric Element. That is, the module numbering is not required to be contiguous. For instance, if a module is mapped physi- cally to a field-replaceable card and in a 13-card cage Fabric Element, cards 3, 5, 6 and 7 may be installed. The vendor may choose to label them as modules 3, 5, 6 and 7 respectively. In this example, the value of fcFeModuleCapacity is 13. The object fcFeModuleFPortCapacity, which also has a maximum value of 256, indicates the maximum number of ports that a given module may con- tain. The value of fcFeModulePortCapacity must not change for a given module. However, a module may be deleted from the Fabric Element and replaced with a module containing a different number of ports. The value of fcFeModuleLastOperStatusChange will indicate that a change took place. Each port within the Fabric Element is uniquely identified by a combina- tion of module number and port number, where port number is an integer in the range 1..fcFeModuleFPortCapacity. As with modules within a Fab- ric Element, ports within a module may be sparsely numbered. That is the port numbering is not required to be contiguous. Likewise, ports may come and go within a module without causing a management reset. 1.2. Structure of the Fabric Element MIB This memo assumes that a Fabric Element has an SNMP entity (manager, agent, or proxy agent) associated with its managed objects. The managed objects are divided as follow: - the Configuration group - the Operation group - the Error group - the Accounting group - the Capability group In each group, scalar objects and table entries are defined. The Configuration group contains configuration and service parameters for the Fabric Element, modules and the F_Ports. The Operation group contains the operational status and parameters of an F_Port. The group also contains the service parameters that have been established between the F_Port and its attached N_Port, if applicable. The Error group contains counters tracking various types of errors detected by each F_Port. The information may be used for diagnostics and/or to derive the quality of the link between an F_Port and its Expiration Date July 1997 [Page 3] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 attached N_Port. The Accounting group contains statistic data suitable for deriving accounting and performance information. The Capability group contains parameters indicating the inherent capa- bility of the Fabric Element and each F_Port. 2. Application of MIB-II to Fabric Element 2.1. The System Group For the purposes of the sysServices object in the System Group of MIB-II [9], Fibre Channel is a data link layer protocol. Thus, for a Fabric Element, sysServices will have the integer value "2". 2.2. The Interface Group The Interface Group of MIB-II defines generic managed objects for manag- ing interfaces. Although each F_Port of a Fabric Element is an inter- face, either the mapping of some interface objects are inappropriate or the definition of some interface objects are insufficient for Fibre Channel. Therefore the Interface Group of MIB-II will not be mapped in this memo. Note that a refinement of the Interface Group is being proposed [11]. When the status of [11] changes to "recommended" in future, the mapping of the Interface Group may then be investigated. 2.3. The SNMP Group The SNMP Group of MIB-II is mandatory for a Fabric Element that supports an SNMP management entity. 3. Object Definitions FCFABRIC-ELEMENT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, experimental, Counter32, Gauge32, TimeTicks FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue, DisplayString FROM SNMPv2-TC; Expiration Date July 1997 [Page 4] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFabric MODULE-IDENTITY LAST-UPDATED "9702070000Z" ORGANIZATION "ANSI X3T11 Fibre Channel Working Group" CONTACT-INFO " Kha Sin Teow Brocade Communications Systems, 2231 Calle De Luna, Santa Clara, CA 95054-1002 U.S.A Tel: +1 408 588 4100 Fax: +1 408 588 4101 Email: khasin@BrocadeComm.COM" DESCRIPTION "The MIB module for Fibre Channel Fabric Element." REVISION "9702070000Z" DESCRIPTION "Version 1.9" ::= { experimental 42 2 } fcFabric OBJECT IDENTIFIER ::= { fibreChannel 2 } -- Fabric Element fcFe OBJECT IDENTIFIER ::= { fcFabric 1 } -- Groups under fcFe fcFeConfig OBJECT IDENTIFIER ::= { fcFe 1 } fcFeOp OBJECT IDENTIFIER ::= { fcFe 2 } fcFeError OBJECT IDENTIFIER ::= { fcFe 3 } fcFeAcct OBJECT IDENTIFIER ::= { fcFe 4 } fcFeCap OBJECT IDENTIFIER ::= { fcFe 5 } -- Type definitions. MilliSeconds ::= INTEGER (0..4294967295) MicroSeconds ::= INTEGER (0..4294967295) FcNameId ::= OCTET STRING (SIZE (8)) -- Worldwide Name or Fibre Channel Name associated with -- an FC entity. It's a Network_Destination_ID or -- Network_Source_ID composed of a value up to 60 bits -- wide, occupying the remaining 8 bytes while the first -- nibble identifies the format of the Name_Identifier with -- hex values: -- 0: ignored -- 1: IEEE 48-bit address, -- 2: IEEE extended, -- 3: Locally assigned, -- 4: 32-bit IP address, -- C: CCITT 60-bit individual address, and Expiration Date July 1997 [Page 5] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 -- E: CCITT 60-bit group address. -- ([1] (19.3, Tables 41-44)). FabricName ::= FcNameId -- The Name Identifier of a Fabric. Each Fabric shall -- provide a unique Fabric Name. -- Only the following formats are allowed: -- CCITT individual & group, IEEE, and Local. -- ([1](19.3.3, 23.7.3)). FcPortName ::= FcNameId -- The Name Identifier associated with a port -- Only the following formats are allowed: -- CCITT individual & group, IEEE, IEEE extended, and Local. -- ([1](19.3.3, 23.6.4 and 23.7.2))). FcAddressId ::= OCTET STRING (SIZE (3)) -- Fibre Channel Address Identifier. A 24-bit value unique -- within the address domain of a Fabric ([1](18.3))). FcRxDataFieldSize ::= INTEGER (128..2112) -- Receive Data_Field Size ([1](23.6.2.4, 23.6.8.5))). FcBbCredit ::= INTEGER (0..32767) -- Buffer-to-buffer Credit -- ([1](23.6.2.2, 23.7.1.2))). -- FC-PH version ([1](23.7.1.1))) FcphVersion ::= INTEGER (0..255) -- Class 1 Stacked Connect Support/Mode -- [1] (23.7.4.2) FcStackedConnMode ::= INTEGER { none (1), transparent (2), lockedDown (3) } -- Class of Service Capability Set FcCosCap ::= INTEGER (0..127) -- bit 0 Class F -- bit 1 Class 1 -- bit 2 Class 2 -- bit 3 Class 3 -- bit 4 Class 4 -- bits 5-7 reserved for future Expiration Date July 1997 [Page 6] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 -- FC-0 Baud Rates (FC-PH(REV 7.3(6.1)) Fc0BaudRate ::= INTEGER { other (1), -- none of below oneEighth (2), -- 155 Mbaud quarter (4), -- 266 Mbaud half (8), -- 532 Mbaud full (16), -- 1 Gbaud double (32), -- 2 Gbaud quadruple (64) -- 4 Gbaud } -- Baud Rate Capability Set Fc0BaudRateCap ::= INTEGER (0..127) -- bit 0 other -- bit 1 oneEighth -- bit 2 quarter -- bit 3 half -- bit 4 full -- bit 5 double -- bit 6 quadruple -- bits 7-8 reserved for future -- FC-0 Media Capability Set Fc0MediaCap ::= INTEGER (0..65535) -- bit 0 unknown -- bit 1 single mode fibre (sm) -- bit 2 multi-mode fibre 50 micron (m5) -- bit 3 multi-mode fibre 62.5 micron (m6) -- bit 4 video cable (tv) -- bit 5 miniature cable (mi) -- bit 6 shielded twisted pair (stp) -- bit 7 unshielded twisted pair (utp) -- bits 8-15 reserved for future use -- A specific FC-0 medium type associated with a port -- FC-PH Rev 7.3 (6.1) Fc0Medium ::= INTEGER { unknown (1), sm (2), -- single mode m5 (4), -- multimode 50 microns m6 (8), -- multimode 62.5 microns tv (16), -- video cable mi (32), -- miniature cable stp (64) -- twisted pair } Expiration Date July 1997 [Page 7] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 -- The FC-0 transmitter type of a port -- FC-PH Rev 7.3 (6.1) Fc0TxType ::= INTEGER { unknown (1), longWaveLaser (2), shortWaveLaser (3), longWaveLED (4), electrical (5), shortWaveLaser-noOFC (6) -- no open fibre control } -- The FC-0 distance range associated with a port transmitter -- [1] (5.7) Fc0Distance ::= INTEGER { unknown (1), long (2), intermediate (3), short (4) } -- Module and Port Capacity FcFeModuleCapacity ::= INTEGER (1..256) FcFeFPortCapacity ::= INTEGER (1..256) -- Module and Port Index FcFeModuleIndex ::= INTEGER (1..256) FcFeFPortIndex ::= INTEGER (1..256) -- The Configuration group -- This group consists of scalar objects and tables. -- It contains the configuration and service parameters -- of the Fabric Element and the F_Ports. -- The group represents a set of parameters associated with -- the Fabric Element or an F_Port to support its N_Ports. -- Implementation of this group is mandatory. fcFabricName OBJECT-TYPE SYNTAX FabricName MAX-ACCESS read-only STATUS current DESCRIPTION "The Name_Identifier of the Fabric to which this Fabric Element belongs. [1](23.7.3), [2](3.1.29), [3](3.1.21)" ::= { fcFeConfig 1 } Expiration Date July 1997 [Page 8] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcElementName OBJECT-TYPE SYNTAX FcNameId MAX-ACCESS read-only STATUS current DESCRIPTION "The Name_Identifier of the Fabric Element. [2](3.1.22), [3](3.1.14)" ::= { fcFeConfig 2 } fcFeModuleCapacity OBJECT-TYPE SYNTAX FcFeModuleCapacity MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of modules in the Fabric Element, regardless of their current state." ::= { fcFeConfig 3 } -- The Module Table. -- This table contains one entry for each module, -- information of the modules. fcFeModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFeModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each module in the Fabric Element, information of the modules." ::= { fcFeConfig 4 } fcFeModuleEntry OBJECT-TYPE SYNTAX FcFeModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the configuration parameters of a module." INDEX { fcFeModuleIndex } ::= { fcFeModuleTable 1 } FcFeModuleEntry ::= SEQUENCE { fcFeModuleIndex FcFeModuleIndex, Expiration Date July 1997 [Page 9] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFeModuleDescr DisplayString, fcFeModuleObjectID OBJECT IDENTIFIER, fcFeModuleOperStatus INTEGER, fcFeModuleLastChange TimeTicks, fcFeModuleFPortCapacity FcFeFPortCapacity } fcFeModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the module within the Fabric Ele- ment for which this entry contains information. This value is never greater than fcFeModuleCapacity." ::= { fcFeModuleEntry 1 } fcFeModuleDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the module. This value should include the full name and version identification of the module. It should contain printable ASCII characters." ::= { fcFeModuleEntry 2 } fcFeModuleObjectID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor's authoritative identification of the module. This value may be allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides a straight-forward and unambiguous means for determining what kind of mod- ule is being managed. For example, this object could take the value 1.3.6.1.4.1.9999.3.9 if vendor 'Neufe Inc.' was assigned the subtree 1.3.6.1.4.1.99649, and had assigned the Expiration Date July 1997 [Page 10] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 identifier 1.3.6.1.4.1.99649.3.9 to its 'FeFiFo-16 Plug- InCard.'" ::= { fcFeModuleEntry 3 } fcFeModuleOperStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- functional offline (2), -- not available testing (3), -- under testing faulty (4) -- defective } ACCESS read-only STATUS current DESCRIPTION "This object indicates the operational status of the mod- ule: online(1) the module is functioning properly; offline(2) the module is not available; testing(3) the module is under testing; and faulty(4) the module is defective in some way." ::= { fcFeModuleEntry 4 } fcFeModuleLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the value of sysUpTime when the module entered its current operational status. A value of zero indicates that the operational status of the module has not changed since the agent last restarted." ::= { fcFeModuleEntry 5 } fcFeModuleFPortCapacity OBJECT-TYPE SYNTAX FcFeFPortCapacity MAX-ACCESS read-only STATUS current DESCRIPTION "The number of F_Ports that can be contained within the module. Within each module, the ports are uniquely num- bered in the range from 1 to fcFeModuleFPortCapacity inclusive. However, the numbers are not required to be contiguous." ::= { fcFeModuleEntry 6 } -- the F_Port Configuration Table. Expiration Date July 1997 [Page 11] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 -- This table contains, one entry for each F_Port, -- configuration parameters of the ports. fcFPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each F_Port in the Fabric Element, configuration and service parameters of the F_Ports. [1](23)" ::= { fcFeConfig 5 } fcFPortConfigEntry OBJECT-TYPE SYNTAX FcFPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the configuration and service param- eters of a F_Port. [1](23)" INDEX { fcFPortConfigModuleIndex, fcFPortConfigFPortIndex } ::= { fcFPortConfigTable 1 } FcFPortConfigEntry ::= SEQUENCE { fcFPortConfigModuleIndex FcFeModuleIndex, fcFPortConfigFPortIndex FcFeFPortIndex, fcFPortName FcPortName, -- F_Port common service parameters fcFPortFcphVersionHigh FcphVersion, fcFPortFcphVersionLow FcphVersion, fcFPortBbCredit FcBbCredit, fcFPortRxBufSize FcRxDataFieldSize, fcFPortRatov MilliSeconds, fcFPortEdtov Expiration Date July 1997 [Page 12] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 MilliSeconds, -- F_Port class service parameters fcFPortCosSupported FcCosCap, fcFPortIntermixSupported TruthValue, fcFPortStackedConnMode FcStackedConnMode, fcFPortClass2SeqDeliv TruthValue, fcFPortClass3SeqDeliv TruthValue, fcFPortHoldTime MicroSeconds, fcFPortBaudRate Fc0BaudRate, fcFPortMedium Fc0Medium, fcFPortTxType Fc0TxType, fcFPortDistance Fc0Distance } fcFPortConfigModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the module containing the F_Port for which this entry contains information." ::= { fcFPortConfigEntry 1 } fcFPortConfigFPortIndex OBJECT-TYPE SYNTAX FcFeFPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the F_Port within the module. This number ranges from 1 to the value of fcFeModule- PortCapacity for the associated module. The value remains constant for the identified F_Port until the module is re-initialized." ::= { fcFPortConfigEntry 2 } Expiration Date July 1997 [Page 13] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortName OBJECT-TYPE SYNTAX FcPortName MAX-ACCESS read-only STATUS current DESCRIPTION "The name identifier of this F_Port. Each F_Port has a unique port name within the address space of the Fabric. [1](19.3.3, 23.7.2), [2](3.1.53) [3](3.1.44)" ::= { fcFPortConfigEntry 3 } -- F_Port common service parameters fcFPortFcphVersionHigh OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The highest or most recent version of FC-PH that the F_Port is configured to support. [1](23.7.1.1), [2](10.4.1)" ::= { fcFPortConfigEntry 4 } fcFPortFcphVersionLow OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest or earliest version of FC-PH that the F_Port is configured to support. [1](23.7.1.1), [2](10.4.1)" ::= { fcFPortConfigEntry 5 } fcFPortBbCredit OBJECT-TYPE SYNTAX FcBbCredit MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of receive buffers available for hold- ing Class 1 connect-request, Class 2 or 3 frames from the attached N_Port. It is for buffer-to-buffer flow control in the direction from the attached N_Port (if applicable) to F_Port. [1](23.7.1.2), [2](10.4.1), [3](15.2)." ::= { fcFPortConfigEntry 6 } Expiration Date July 1997 [Page 14] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortRxBufSize OBJECT-TYPE SYNTAX FcRxDataFieldSize MAX-ACCESS read-only STATUS current DESCRIPTION "The largest Data_Field Size (in octets) for an FT_1 frame that can be received by the F_Port. [1](17.4, 23.7.1.4)" ::= { fcFPortConfigEntry 7 } fcFPortRatov OBJECT-TYPE SYNTAX MilliSeconds MAX-ACCESS read-only STATUS current DESCRIPTION "The Resource_Allocation_Timeout Value configured for the F_Port. This is used as the timeout value for determin- ing when to reuse an N_Port resource such as a Recov- ery_Qualifier. It represents E_D_TOV (see next object) plus twice the maximum time that a frame may be delayed within the Fabric and still be delivered. [1](23.7.1.6, 29.2.1.3), [3](14.4.1.2)." ::= { fcFPortConfigEntry 8 } fcFPortEdtov OBJECT-TYPE SYNTAX MilliSeconds MAX-ACCESS read-only STATUS current DESCRIPTION "The E_D_TOV value configured for the F_Port. The Error_Detect_Timeout Value is used as the timeout value for detecting an error condition. [1](23.7.1.5, 29.2.1.2), [3](14.4.1.4)" ::= { fcFPortConfigEntry 9 } -- F_Port class service parameters fcFPortCosSupported OBJECT-TYPE SYNTAX FcCosCap MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the set of Classes of Service sup- ported by the F_Port. [1](23.7.4.1), [2](Table 10.2), [3](15.3.5.1, 15.3.5.2)" Expiration Date July 1997 [Page 15] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 ::= { fcFPortConfigEntry 10 } fcFPortIntermixSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not the F_Port supports an Intermixed Dedicated Connection. [1](23.7.4.2)" ::= { fcFPortConfigEntry 11 } fcFPortStackedConnMode OBJECT-TYPE SYNTAX FcStackedConnMode MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the mode of Stacked Connect supported by the F_Port. [1](23.7.4.2)" ::= { fcFPortConfigEntry 12 } fcFPortClass2SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not Class 2 Sequential Delivery is supported by the F_Port. [1](23.7.4.2)" ::= { fcFPortConfigEntry 13 } fcFPortClass3SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not Class 3 Sequential Delivery is supported by the F_Port. [1](23.7.4.2)" ::= { fcFPortConfigEntry 14 } Expiration Date July 1997 [Page 16] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortHoldTime OBJECT-TYPE SYNTAX MicroSeconds MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum time (in microseconds) that the F_Port shall hold a frame before discarding the frame if it is unable to deliver the frame. The value 0 means that the F_Port does not support this parameter." ::= { fcFPortConfigEntry 15 } fcFPortBaudRate OBJECT-TYPE SYNTAX Fc0BaudRate MAX-ACCESS read-only STATUS current DESCRIPTION "The FC-0 baud rate of the F_Port. [1](5.1)" ::= { fcFPortConfigEntry 16 } fcFPortMedium OBJECT-TYPE SYNTAX Fc0Medium MAX-ACCESS read-only STATUS current DESCRIPTION "The FC-0 medium of the F_Port. [1](5.1)" ::= { fcFPortConfigEntry 17 } fcFPortTxType OBJECT-TYPE SYNTAX Fc0TxType MAX-ACCESS read-only STATUS current DESCRIPTION "The FC-0 transmitter type of the F_Port. [1](5.1)" ::= { fcFPortConfigEntry 18 } fcFPortDistance OBJECT-TYPE SYNTAX Fc0Distance MAX-ACCESS read-only STATUS current DESCRIPTION "The FC-0 distance range of the F_Port transmitter. [1](5.1)" ::= { fcFPortConfigEntry 19 } Expiration Date July 1997 [Page 17] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 -- the Operation group -- This group consists of tables that contains operational -- status and established service parameters for the Fabric -- Element and the attached N_Ports. -- Implementation of this group is mandatory. -- The F_Port Operation table -- This table contains, one entry for each F_Port, -- the operational status and parameters of the F_Ports. fcFPortOperTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFPortOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each F_Port in the Fabric Element, operational status and parameters of the F_Ports." ::= { fcFeOp 1 } fcFPortOperEntry OBJECT-TYPE SYNTAX FcFPortOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing operational status and parameters of a F_Port. [1]" INDEX { fcFPortOperModuleIndex, fcFPortOperFPortIndex } ::= { fcFPortOperTable 1 } FcFPortOperEntry ::= SEQUENCE { fcFPortOperModuleIndex FcFeModuleIndex, fcFPortOperFPortIndex FcFeFPortIndex, fcFPortID FcAddressId, fcFPortAttachedPortName FcPortName, fcFPortConnectedPort FcAddressId, fcFPortBbCreditAvailable Expiration Date July 1997 [Page 18] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 Gauge32 } fcFPortOperModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the module containing the F_Port for which this entry contains information." ::= { fcFPortOperEntry 1 } fcFPortOperFPortIndex OBJECT-TYPE SYNTAX FcFeFPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the F_Port within the module. This number ranges from 1 to the value of fcFeModule- PortCapacity for the associated module. The value remains constant for the identified F_Port until the module is re-initialized." ::= { fcFPortOperEntry 2 } fcFPortID OBJECT-TYPE SYNTAX FcAddressId MAX-ACCESS read-only STATUS current DESCRIPTION "The address identifier by which this F_Port is identi- fied within the Fabric. The F_Port may assign its address identifier to its attached N_Port during Fabric Login. [1](23.3), [2](4.5.1)" ::= { fcFPortOperEntry 3 } fcFPortAttachedPortName OBJECT-TYPE SYNTAX FcPortName MAX-ACCESS read-only STATUS current DESCRIPTION "The port name of the attached N_Port, if applicable. If the value of this object is '0000000000000000'H, this F_Port has no N_Port attached to it. [1](23.6.4)" ::= { fcFPortOperEntry 4 } Expiration Date July 1997 [Page 19] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortConnectedPort OBJECT-TYPE SYNTAX FcAddressId MAX-ACCESS read-only STATUS current DESCRIPTION "The address identifier of the destination F_Port with which this F_Port is currently engaged in a Class 1 con- nection. If the value of this object is '000000'H, this F_Port is not engaged in a Class 1 connection. [1](28)" ::= { fcFPortOperEntry 5 } fcFPortBbCreditAvailable OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of buffers currently available for receiving frames from the attached port in the buffer-to-buffer flow control. The value should be less than or equal to fcFPortBbCredit. [1](26)" ::= { fcFPortOperEntry 6 } -- The Fabric Login table -- -- This table contains, one entry for each F_Port in the -- Fabric Element, the Service Parameters that have been -- established from the most recent Fabric Login -- (implicit or explicit). fcFPortFlogiTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFPortFlogiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each F_Port in the Fabric Element, services parameters established from the most recent Fabric Login (explicit or implicit). [1](23.3)" ::= { fcFeOp 2 } Expiration Date July 1997 [Page 20] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortFlogiEntry OBJECT-TYPE SYNTAX FcFPortFlogiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing service parameters established from a successful Fabric Login. [1](23.3)" INDEX { fcFPortFlogiModuleIndex, fcFPortFlogiFPortIndex } ::= { fcFPortFlogiTable 1 } FcFPortFlogiEntry ::= SEQUENCE { fcFPortFlogiModuleIndex FcFeModuleIndex, fcFPortFlogiFPortIndex FcFeFPortIndex, fcFPortFcphVersionAgreed FcphVersion, fcFPortNPortBbCredit FcBbCredit, fcFPortNPortRxDataFieldSize FcRxDataFieldSize, fcFPortCosSuppAgreed FcCosCap, fcFPortIntermixSuppAgreed TruthValue, fcFPortStackedConnModeAgreed FcStackedConnMode, fcFPortClass2SeqDelivAgreed TruthValue, fcFPortClass3SeqDelivAgreed TruthValue } fcFPortFlogiModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the module containing the F_Port for which this entry contains information." ::= { fcFPortFlogiEntry 1 } Expiration Date July 1997 [Page 21] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortFlogiFPortIndex OBJECT-TYPE SYNTAX FcFeFPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the F_Port within the module. This number ranges from 1 to the value of fcFeModule- PortCapacity for the associated module. The value remains constant for the identified F_Port until the module is re-initialized." ::= { fcFPortFlogiEntry 2 } fcFPortFcphVersionAgreed OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The version of FC-PH that the F_Port has agreed to sup- port from the Fabric Login [1](23.7.1.1)" ::= { fcFPortFlogiEntry 3 } fcFPortNPortBbCredit OBJECT-TYPE SYNTAX FcBbCredit MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames to be transmitted to the attached N_Port. It is for buffer- to-buffer flow control in the direction from F_Port to N_Port. [1](23.6.2.2)" ::= { fcFPortFlogiEntry 4 } fcFPortNPortRxDataFieldSize OBJECT-TYPE SYNTAX FcRxDataFieldSize MAX-ACCESS read-only STATUS current DESCRIPTION "The Receive Data Field Size of the attached N_Port. This is a binary value that specifies the largest Data Field Size for an FT_1 frame that can be received by the N_Port. The value is in number of bytes and ranges from 128 to 2112 inclusive. [1](23.6.2.4)" Expiration Date July 1997 [Page 22] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 ::= { fcFPortFlogiEntry 5 } fcFPortCosSuppAgreed OBJECT-TYPE SYNTAX FcCosCap MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating that the attached N_Port has requested the F_Port for the support of classes of services and the F_Port has granted the request. [1](23.6.7.1, 23.7.4.1)" ::= { fcFPortFlogiEntry 6 } fcFPortIntermixSuppAgreed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating that the attached N_Port has requested the F_Port for the support of Intermix and the F_Port has granted the request. This flag is only valid if Class 1 service is supported. [1](23.6.7.2, 23.7.4.2)" ::= { fcFPortFlogiEntry 7 } fcFPortStackedConnModeAgreed OBJECT-TYPE SYNTAX FcStackedConnMode MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating whether the F_Port has agreed to sup- port stacked connect from the Fabric Login. This is only meaningful if Class 1 service has been agreed. [1](23.6.7.2, 23.7.4.2)" ::= { fcFPortFlogiEntry 8 } fcFPortClass2SeqDelivAgreed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether the F_Port has agreed to sup- port Class 2 sequential delivery from the Fabric Login. This is only meaningful if Class 2 service has been agreed. [1](23.6.7.1, 23.7.4.1)" Expiration Date July 1997 [Page 23] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 ::= { fcFPortFlogiEntry 9 } fcFPortClass3SeqDelivAgreed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether the F_Port has agreed to sup- port Class 3 sequential delivery from the Fabric Login. This is only meaningful if Class 3 service has been agreed. [1](23.6.7.1, 23.7.4.1)" ::= { fcFPortFlogiEntry 10 } -- the F_Port Physical Level table -- This table contains, one entry for each F_Port in the -- Fabric Element, the physical level status and parameters -- of the F_Ports. fcFPortPhysTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFPortPhysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each F_Port in the Fabric Element, physical level status and parameters of the F_Ports. [1](16.5, 29.2)" ::= { fcFeOp 3 } fcFPortPhysEntry OBJECT-TYPE SYNTAX FcFPortPhysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing physical level status and parameters of a F_Port. [1](16.5, 29.2)" INDEX { fcFPortPhysModuleIndex, fcFPortPhysFPortIndex } ::= { fcFPortPhysTable 1 } Expiration Date July 1997 [Page 24] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 FcFPortPhysEntry ::= SEQUENCE { fcFPortPhysModuleIndex FcFeModuleIndex, fcFPortPhysFPortIndex FcFeFPortIndex, fcFPortPhysAdminStatus INTEGER, fcFPortPhysOperStatus INTEGER, fcFPortPhysLastChange TimeTicks, fcFPortPhysRttov MilliSeconds } fcFPortPhysModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the module containing the F_Port for which this entry contains information." ::= { fcFPortPhysEntry 1 } fcFPortPhysFPortIndex OBJECT-TYPE SYNTAX FcFeFPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the F_Port within the module. This number ranges from 1 to the value of fcFeModule- PortCapacity for the associated module. The value remains constant for the identified F_Port until the module is re-initialized." ::= { fcFPortPhysEntry 2 } fcFPortPhysAdminStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- place port online offline (2), -- take port offline testing (3) -- initiate test procedures } ACCESS read-write STATUS mandatory DESCRIPTION Expiration Date July 1997 [Page 25] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 "The desired state of the F_Port. A management station may place the F_Port in a desired state by setting this object accordingly. The testing(3) state indicates that no operational frames can be passed. When a Fabric Ele- ment initializes, all F_Ports start with fcFPortPhysAd- minStatus in the offline(2) state. As the result of either explicit management action or per configuration information accessible by the Fabric Element, fcFPort- PhysAdminStatus is then changed to either the online(1) or testing(3) states, or remains in the offline state. [1](16.5)" ::= { fcFPortPhysEntry 3 } fcFPortPhysOperStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- Login may proceed offline (2), -- Login cannot proceed testing (3), -- port is under test link-failure (4) -- failure after online/testing -- Other values may be used to indicate -- diagnostic for failed test. } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational status of the F_Port. The testing(3) indicates that no operational frames can be passed. If fcFPortPhysAdminStatus is offline(2) then fcFPortPhysOperStatus should be offline(2). If fcFPortPhysAdminStatus is changed to online(1) then fcFPortPhysOperStatus should change to online(1) if the F_Port is ready to accept Fabric Login request from the attached N_Port; it should proceed and remain in the link-failure(4) state if and only if there is a fault that prevents it from going to the online(1) state. [1](16.5)" ::= { fcFPortPhysEntry 4 } fcFPortPhysLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the F_Port entered its current operational status. A value of Expiration Date July 1997 [Page 26] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 zero indicates that the F_Port's operational status has not changed since the agent last restarted." ::= { fcFPortPhysEntry 5 } fcFPortPhysRttov OBJECT-TYPE SYNTAX MilliSeconds MAX-ACCESS read-write STATUS current DESCRIPTION "The Receiver_Transmitter_Timeout value of the F_Port. This is used by the receiver logic to detect Loss of Synchronization. [1](29.2.1.1)" ::= { fcFPortPhysEntry 6 } -- the Error group -- This group consists of tables that contain information about -- the various types of errors detected. The management station -- may use the information in this group to determine the -- quality of the link between the F_Port and its attached N_Port. -- Implementation of this group is optional. -- the F_Port Error table -- This table contains, one entry for each F_Port in the Fabric -- Element, counters recording numbers of errors detected -- since the management agent re-initialized. -- The first 6 columnar objects after the port index corresponds -- to the counters in the Link Error Status Block ([1](29.8)). fcFPortErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFPortErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each F_Port, coun- ters that record the numbers of errors detected. [1](29)" ::= { fcFeError 1 } fcFPortErrorEntry OBJECT-TYPE SYNTAX FcFPortErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing error counters of a F_Port. Expiration Date July 1997 [Page 27] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 [1](29)" INDEX { fcFPortErrorModuleIndex, fcFPortErrorFPortIndex } ::= { fcFPortErrorTable 1 } FcFPortErrorEntry ::= SEQUENCE { fcFPortErrorModuleIndex FcFeModuleIndex, fcFPortErrorFPortIndex FcFeFPortIndex, fcFPortLinkFailures Counter32, fcFPortSyncLosses Counter32, fcFPortSigLosses Counter32, fcFPortPrimSeqProtoErrors Counter32, fcFPortInvalidTxWords Counter32, fcFPortInvalidCrcs Counter32, fcFPortDelimiterErrors Counter32, fcFPortAddressIdErrors Counter32, fcFPortLinkResetIns Counter32, fcFPortLinkResetOuts Counter32, fcFPortOlsIns Counter32, fcFPortOlsOuts Counter32 } fcFPortErrorModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the module containing the F_Port for which this entry contains information." ::= { fcFPortErrorEntry 1 } Expiration Date July 1997 [Page 28] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortErrorFPortIndex OBJECT-TYPE SYNTAX FcFeFPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the F_Port within the module. This number ranges from 1 to the value of fcFeModule- PortCapacity for the associated module. The value remains constant for the identified F_Port until the module is re-initialized." ::= { fcFPortErrorEntry 2 } fcFPortLinkFailures OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of link failures detected by this F_Port. [1](29.8, Figure 82)" ::= { fcFPortErrorEntry 3 } fcFPortSyncLosses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of loss of synchronization detected by the F_Port. [1](12.1.1.2, 29.8)" ::= { fcFPortErrorEntry 4 } fcFPortSigLosses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of loss of signal detected by the F_Port. [1](12.1.1.2, 29.8)" ::= { fcFPortErrorEntry 5 } fcFPortPrimSeqProtoErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of primitive sequence protocol errors Expiration Date July 1997 [Page 29] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 detected by the F_Port. [1](29.3.3, 29.8 )" ::= { fcFPortErrorEntry 6 } fcFPortInvalidTxWords OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid transmission word detected by the F_Port. [1](29.3.2, 29.8)" ::= { fcFPortErrorEntry 7 } fcFPortInvalidCrcs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid CRC detected by this F_Port. [1](29.8)" ::= { fcFPortErrorEntry 8 } fcFPortDelimiterErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Delimiter Errors detected by this F_Port. [1](29.9, Table 112)" ::= { fcFPortErrorEntry 9 } fcFPortAddressIdErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of address identifier errors detected by this F_Port. [1](29.9, Table 112)" ::= { fcFPortErrorEntry 10 } Expiration Date July 1997 [Page 30] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortLinkResetIns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Link Reset Protocol received by this F_Port from the attached N_Port. [1](16.6.5, 29.9)" ::= { fcFPortErrorEntry 11 } fcFPortLinkResetOuts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Link Reset Protocol issued by this F_Port to the attached N_Port. [1](16.6.5, 29.9)" ::= { fcFPortErrorEntry 12 } fcFPortOlsIns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Offline Sequence received by this F_Port. [1](16.4.3)" ::= { fcFPortErrorEntry 13 } fcFPortOlsOuts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Offline Sequence issued by this F_Port. [1](16.4.3)" ::= { fcFPortErrorEntry 14 } -- Accounting Groups: -- (1) Class 1 Accounting Group, -- (2) Class 2 Accounting Group, and -- (3) Class 3 Accounting Group. -- Each group consists of a table that contains accounting -- information for the F_Ports in the Fabric Element. Expiration Date July 1997 [Page 31] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 -- Implementation of each group is optional. -- the Class 1 Accounting table -- This table contains, one entry for each F_Port in the Fabric -- Element, Counter32s for certain types of events occurred in the -- the F_Ports since the the management agent has re-initialized. -- Implementation of this group is optional. fcFPortC1AcctTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFPortC1AcctEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each F_Port in the Fabric Element, Class 1 accounting information recorded since the management agent has re-initialized." ::= { fcFeAcct 1 } fcFPortC1AcctEntry OBJECT-TYPE SYNTAX FcFPortC1AcctEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing Class 1 accounting information for each F_Port." INDEX { fcFPortC1AcctModuleIndex, fcFPortC1AcctFPortIndex } ::= { fcFPortC1AcctTable 1 } FcFPortC1AcctEntry ::= SEQUENCE { fcFPortC1AcctModuleIndex FcFeModuleIndex, fcFPortC1AcctFPortIndex FcFeFPortIndex, fcFPortC1InConnections Counter32, fcFPortC1OutConnections Counter32, fcFPortC1FbsyFrames Counter32, fcFPortC1FrjtFrames Counter32, fcFPortC1ConnTime Counter32, fcFPortC1InFrames Expiration Date July 1997 [Page 32] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 Counter32, fcFPortC1OutFrames Counter32, fcFPortC1InOctets Counter32, fcFPortC1OutOctets Counter32, fcFPortC1Discards Counter32 } fcFPortC1AcctModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the module containing the F_Port for which this entry contains information." ::= { fcFPortC1AcctEntry 1 } fcFPortC1AcctFPortIndex OBJECT-TYPE SYNTAX FcFeFPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the F_Port within the module. This number ranges from 1 to the value of fcFeModule- PortCapacity for the associated module. The value remains constant for the identified F_Port until the module is re-initialized." ::= { fcFPortC1AcctEntry 2 } fcFPortC1InConnections OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 connections successfully estab- lished in which the attached N_Port is the source of the connect-request. [1](28)" ::= { fcFPortC1AcctEntry 3 } Expiration Date July 1997 [Page 33] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortC1OutConnections OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 connections successfully estab- lished in which the attached N_Port is the destination of the connect-request. [1](28)" ::= { fcFPortC1AcctEntry 4 } fcFPortC1FbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of F_BSY frames generated by this F_Port against Class 1 connect-request. [1](20.3.3.1)" ::= { fcFPortC1AcctEntry 5 } fcFPortC1FrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of F_RJT frames generated by this F_Port against Class 1 connect-request. [1](20.3.3.3)" ::= { fcFPortC1AcctEntry 6 } fcFPortC1ConnTime OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The cumulative time that this F_Port has been engaged in Class 1 connection. The amount of time of each connec- tion is counted in octets from after a connect-request has been accepted until the connection is disengaged, either by an EOFdt or Link Reset. [1](22.1)" ::= { fcFPortC1AcctEntry 7 } Expiration Date July 1997 [Page 34] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortC1InFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 frames (other than Class 1 con- nect-request) received by this F_Port from its attached N_Port. [1](20.1)" ::= { fcFPortC1AcctEntry 8 } fcFPortC1OutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 frames (other than Class 1 con- nect-request) delivered through this F_Port to its attached N_Port. [1](20.1)" ::= { fcFPortC1AcctEntry 9 } fcFPortC1InOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 frame octets, including the frame delimiters, received by this F_Port from its attached N_Port [1](20.1))" ::= { fcFPortC1AcctEntry 10 } fcFPortC1OutOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 frame octets, including the frame delimiters, delivered through this F_Port its attached N_Port. [1](20.1)" ::= { fcFPortC1AcctEntry 11 } Expiration Date July 1997 [Page 35] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortC1Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 frames discarded by this F_Port. [1](20.1)" ::= { fcFPortC1AcctEntry 12 } -- the Class 2 Accounting table -- This table contains, one entry for each F_Port in the Fabric -- Element, Counter32s for certain types of events occurred in the -- the F_Ports since the the management agent has re-initialized. -- Implementation of this group is optional. fcFPortC2AcctTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFPortC2AcctEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each F_Port in the Fabric Element, Class 2 accounting information recorded since the management agent has re-initialized." ::= { fcFeAcct 2 } fcFPortC2AcctEntry OBJECT-TYPE SYNTAX FcFPortC2AcctEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing Class 2 accounting information for each F_Port." INDEX { fcFPortC2AcctModuleIndex, fcFPortC2AcctFPortIndex } ::= { fcFPortC2AcctTable 1 } FcFPortC2AcctEntry ::= SEQUENCE { fcFPortC2AcctModuleIndex FcFeModuleIndex, fcFPortC2AcctFPortIndex FcFeFPortIndex, fcFPortC2InFrames Counter32, fcFPortC2OutFrames Counter32, Expiration Date July 1997 [Page 36] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortC2InOctets Counter32, fcFPortC2OutOctets Counter32, fcFPortC2Discards Counter32, fcFPortC2FbsyFrames Counter32, fcFPortC2FrjtFrames Counter32 } fcFPortC2AcctModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the module containing the F_Port for which this entry contains information." ::= { fcFPortC2AcctEntry 1 } fcFPortC2AcctFPortIndex OBJECT-TYPE SYNTAX FcFeFPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the F_Port within the module. This number ranges from 1 to the value of fcFeModule- PortCapacity for the associated module. The value remains constant for the identified F_Port until the module is re-initialized." ::= { fcFPortC2AcctEntry 2 } fcFPortC2InFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames received by this F_Port from its attached N_Port. [1](20.2)" ::= { fcFPortC2AcctEntry 3 } Expiration Date July 1997 [Page 37] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortC2OutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames delivered through this F_Port to its attached N_Port. [1](20.2)" ::= { fcFPortC2AcctEntry 4 } fcFPortC2InOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frame octets, including the frame delimiters, received by this F_Port from its attached N_Port. [1](20.2)" ::= { fcFPortC2AcctEntry 5 } fcFPortC2OutOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frame octets, including the frame delimiters, delivered through this F_Port to its attached N_Port. [1](20.2)" ::= { fcFPortC2AcctEntry 6 } fcFPortC2Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames discarded by this F_Port. [1](22.2)" ::= { fcFPortC2AcctEntry 7 } Expiration Date July 1997 [Page 38] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortC2FbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of F_BSY frames generated by this F_Port against Class 2 frames. [1](20.3.3.1)" ::= { fcFPortC2AcctEntry 8 } fcFPortC2FrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of F_RJT frames generated by this F_Port against Class 2 frames. [1](20.3.3.3)" ::= { fcFPortC2AcctEntry 9 } -- the Class 3 Accounting Group -- This table contains, one entry for each F_Port in the Fabric -- Element, Counter32s for certain types of events occurred in the -- the F_Ports since the management agent has re-initialized. -- Implementation of this group is optional. fcFPortC3AcctTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFPortC3AcctEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each F_Port in the Fabric Element, Class 3 accounting information recorded since the management agent has re-initialized." ::= { fcFeAcct 3 } fcFPortC3AcctEntry OBJECT-TYPE SYNTAX FcFPortC3AcctEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing Class 3 accounting information for each F_Port." INDEX { fcFPortC3AcctModuleIndex, fcFPortC3AcctFPortIndex } ::= { fcFPortC3AcctTable 1 } Expiration Date July 1997 [Page 39] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 FcFPortC3AcctEntry ::= SEQUENCE { fcFPortC3AcctModuleIndex FcFeModuleIndex, fcFPortC3AcctFPortIndex FcFeFPortIndex, fcFPortC3InFrames Counter32, fcFPortC3OutFrames Counter32, fcFPortC3InOctets Counter32, fcFPortC3OutOctets Counter32, fcFPortC3Discards Counter32 } fcFPortC3AcctModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the module containing the F_Port for which this entry contains information." ::= { fcFPortC3AcctEntry 1 } fcFPortC3AcctFPortIndex OBJECT-TYPE SYNTAX FcFeFPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the F_Port within the module. This number ranges from 1 to the value of fcFeModule- PortCapacity for the associated module. The value remains constant for the identified F_Port until the module is re-initialized." ::= { fcFPortC3AcctEntry 2 } fcFPortC3InFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames received by this F_Port from its attached N_Port. Expiration Date July 1997 [Page 40] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 [1](22.3)" ::= { fcFPortC3AcctEntry 3 } fcFPortC3OutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames delivered through this F_Port to its attached N_Port. [1](22.3)" ::= { fcFPortC3AcctEntry 4 } fcFPortC3InOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frame octets, including the frame delimiters, received by this F_Port from its attached N_Port. [1](22.3))" ::= { fcFPortC3AcctEntry 5 } fcFPortC3OutOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frame octets, including the frame delimiters, delivered through this F_Port to its attached N_Port. [1](22.3)" ::= { fcFPortC3AcctEntry 6 } fcFPortC3Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames discarded by this F_Port. [1](22.3)" ::= { fcFPortC3AcctEntry 7 } -- The Capability Group - consists of a table describing Expiration Date July 1997 [Page 41] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 -- information about what each F_Port is inherently capable -- of operating or supporting. -- A capability may be used, as expressed in its respective -- object value in the Configuration group. -- Implementation of this group is optional. fcFPortCapTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFPortCapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each F_Port, the capabilities of the port within the Fabric Element. [1](23)" ::= { fcFeCap 1 } fcFPortCapEntry OBJECT-TYPE SYNTAX FcFPortCapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the capabilities of a F_Port. [1](23)" INDEX { fcFPortCapModuleIndex, fcFPortCapFPortIndex } ::= { fcFPortCapTable 1 } FcFPortCapEntry ::= SEQUENCE { fcFPortCapModuleIndex FcFeModuleIndex, fcFPortCapFPortIndex FcFeFPortIndex, fcFPortCapFcphVersionHigh FcphVersion, fcFPortCapFcphVersionLow FcphVersion, fcFPortCapBbCreditMax FcBbCredit, fcFPortCapBbCreditMin FcBbCredit, fcFPortCapRxDataFieldSizeMax FcRxDataFieldSize, fcFPortCapRxDataFieldSizeMin FcRxDataFieldSize, fcFPortCapCos Expiration Date July 1997 [Page 42] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 FcCosCap, fcFPortCapIntermix TruthValue, fcFPortCapStackedConnMode FcStackedConnMode, fcFPortCapClass2SeqDeliv TruthValue, fcFPortCapClass3SeqDeliv TruthValue, fcFPortCapHoldTimeMax MicroSeconds, fcFPortCapHoldTimeMin MicroSeconds, fcFPortCapBaudRates Fc0BaudRateCap, fcFPortCapMedia Fc0MediaCap } fcFPortCapModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the module containing the F_Port for which this entry contains information." ::= { fcFPortCapEntry 1 } fcFPortCapFPortIndex OBJECT-TYPE SYNTAX FcFeFPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the F_Port within the module. This number ranges from 1 to the value of fcFeModule- PortCapacity for the associated module. The value remains constant for the identified F_Port until the module is re-initialized." ::= { fcFPortCapEntry 2 } fcFPortCapFcphVersionHigh OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The highest or most recent version of FC-PH that the Expiration Date July 1997 [Page 43] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 F_Port is capable of supporting. [1](23.7.1.1), [2](10.4.1)" ::= { fcFPortCapEntry 3 } fcFPortCapFcphVersionLow OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest or earliest version of FC-PH that the F_Port is capable of supporting. [1](23.7.1.1), [2](10.4.1)" ::= { fcFPortCapEntry 4 } fcFPortCapBbCreditMax OBJECT-TYPE SYNTAX FcBbCredit MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of receive buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames from the attached N_Port. [1](23.7.1.2), [2](10.4.1), [3](15.2)" ::= { fcFPortCapEntry 5 } fcFPortCapBbCreditMin OBJECT-TYPE SYNTAX FcBbCredit MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum number of receive buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames from the attached N_Port. [1](23.7.1.2), [2](10.4.1), [3](15.2)" ::= { fcFPortCapEntry 6 } fcFPortCapRxDataFieldSizeMax OBJECT-TYPE SYNTAX FcRxDataFieldSize MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum size in bytes of the Data Field in a frame that the F_Port is capable of receiving from its attached N_Port. [1](23.6.2.4)" ::= { fcFPortCapEntry 7 } Expiration Date July 1997 [Page 44] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortCapRxDataFieldSizeMin OBJECT-TYPE SYNTAX FcRxDataFieldSize MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum size in bytes of the Data Field in a frame that the F_Port is capable of receiving from its attached N_Port. [1](23.6.2.4)" ::= { fcFPortCapEntry 8 } fcFPortCapCos OBJECT-TYPE SYNTAX FcCosCap MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the set of Classes of Service that the F_Port is capable of supporting. [1](23.7.4.1), [2](Table 10.2), [3](15.3.5.1, 15.3.5.2)" ::= { fcFPortCapEntry 9 } fcFPortCapIntermix OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not the F_Port is capable of supporting the intermixing of Class 2 and Class 3 frames during a Class 1 connection. This flag is only valid if the port is capable of supporting Class 1 ser- vice. [1](23.7.4.2)" ::= { fcFPortCapEntry 10 } fcFPortCapStackedConnMode OBJECT-TYPE SYNTAX FcStackedConnMode MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the mode of Stacked Connect request that the F_Port is capable of supporting. [1](23.7.4.2)" ::= { fcFPortCapEntry 11 } Expiration Date July 1997 [Page 45] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 fcFPortCapClass2SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not the F_Port is capable of supporting Class 2 Sequential Delivery. [1](23.7.4.2)" ::= { fcFPortCapEntry 12 } fcFPortCapClass3SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not the F_Port is capable of supporting Class 3 Sequential Delivery. [1](23.7.4.2)" ::= { fcFPortCapEntry 13 } fcFPortCapHoldTimeMax OBJECT-TYPE SYNTAX MicroSeconds MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum holding time (in microseconds) that the F_Port is capable of supporting." ::= { fcFPortCapEntry 14 } fcFPortCapHoldTimeMin OBJECT-TYPE SYNTAX MicroSeconds MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum holding time (in microseconds) that the F_Port is capable of supporting." ::= { fcFPortCapEntry 15 } fcFPortCapBaudRates OBJECT-TYPE SYNTAX Fc0BaudRateCap MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the set of baud rates that the F_Port is capable of supporting. [1](5.1)" Expiration Date July 1997 [Page 46] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 ::= { fcFPortCapEntry 16 } fcFPortCapMedia OBJECT-TYPE SYNTAX Fc0MediaCap MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the set of media that the F_Port is capable of supporting. [1](5.1)" ::= { fcFPortCapEntry 17 } END -- End of Object Definitions 4. Acknowledgements The editors would like to thank the following individuals for their assistance and constructive comments: John Y. Chu, IBM Yakov Rekhter, IBM Martin Sachs, IBM Dan Eisenhauer, IBM Beth Vanderbeck, IBM Carl Zeitler, IBM Paul Griffiths, IBM KC Chennappan, IBM Jessie Haug, IBM Bob Cornelius, ANCOR Lansing Sloan, LLNL Paul Rupert, LLNL Rich Taborak, Amdahl Steve Wilson, Amdahl Jerry Rouse, IBM Dal Allan, ENDL Hubert Huot, IBM Venkat Rao, HP Amir Artsi, RADWAY International Ltd. Bent Stoevhase, Brocade CommunicationsJeff Meyer, HP 5. References [1] Fibre Channel Physical and Signaling Interface (FC-PH), Rev 4.3, June 1, 1994. Working Draft Proposed American National Standard for Information Systems, X3.230-AM1:1996, Computer and Business Equip- ment Manufacturers Association, Washington, DC. [2] Fibre Channel Fabric Requirements (FC-FG), Rev 3.3, Oct 1995. Work- ing Draft Proposed American National Standard for Information Sys- tems, X3T11/958D, Computer and Business Equipment Manufacturers Association, Washington, DC. Expiration Date July 1997 [Page 47] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 [3] Fibre Channel Cross-point Switch Fabric and Switch Control Require- ments (FC-SW), Rev 1.5, March 1995. Working Draft Proposed American National Standard for Information Systems, X3T11/959D, Computer and Business Equipment Manufacturers Association, Washington, DC. [4] Fibre Channel Generic Services (FC-GS), Rev 3.0, Oct 11, 1995. Working Draft Proposed American National Standard for Information Systems, X3T11/1050D, Computer and Business Equipment Manufacturers Association, Washington, DC. [5] Rose M., and K. McCloghrie, "Structure and Identification of Man- agement Information for TCP/IP-based internets", RFC 1155, Perfor- mance Systems International, Hughes LAN Systems, May 1990. [6] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions", RFC 1212, Performance Systems International, Hughes LAN Systems, March 1991. [7] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple Network Management Protocol", RFC 1157, SNMP Research, Performance Systems International, Performance Systems International, MIT Laboratory for Computer Science, May 1990. [8] McCloghrie K., and M. Rose, Editors, "Management Information Base for Network Management of TCP/IP-based internets", RFC 1213, Per- formance Systems International, March 1991. [9] Chu, J.Y., "Definitions of Managed Objects for the Node in Fibre Channel Standard using SMIv2", Internet draft, Version 1.5, Septem- ber 5, 1995. [10] McCloghrie K., and F. Kastenholz, Editors, "Evolution of the Inter- faces Group of MIB-II", RFC 1573, Hughes LAN Systems, FTP Software, January 1994. [11] Fibre Channel Arbitrated Loop (FC-AL), Rev 5.1, Mar 1996. Working Draft Proposed American National Standard for Information Systems, X3T11/960D, Computer and Business Equipment Manufacturers Expiration Date July 1997 [Page 48] INTERNET DRAFT FC Fabric Element MIB February 7, 1997 Association, Washington, DC. [12] McMaster D., and K. McCloghrie, Editors, "Definitions of Managed Objects for IEEE 802.3 Repeater Devices", RFC1516, Synoptics Commu- nications, Inc., Hughes LAN Systems Inc., September 1993. [13] Fibre Channel Physical and Signaling Interface (FC-PH-2), Rev 7.3, January 5, 1996. Working Draft Proposed American National Standard for Information Systems, X3.xxx:1996, Computer and Business Equip- ment Manufacturers Association, Washington, DC. 6. Security Considerations Security issues are not discussed in this memo. 7. Editors' Addresses Kha Sin Teow Brocade Communications Systems, Inc. 2231 Calle De Luna Santa Clara, CA 95054-1002 U.S.A. Phone: +1 408-588-4100 Email: khasin@BrocadeComm.COM Expiration Date July 1997 [Page 49]